10 CFR §429.20
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Sampling plan for selection of units for testing.
- (1)The requirements of § 429.11 are applicable to residential clothes washers; and
- (2)For each basic model of residential clothes washers, a sample of sufficient size shall be randomly selected and tested to ensure that—
- (i)Any represented value of the integrated water factor, the estimated annual operating cost, the energy or water consumption, or other measure of energy or water consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:
- (ii)Any represented value of the integrated modified energy factor, energy efficiency ratio, water efficiency ratio, or other measure of energy or water consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:
- (3)The clothes container capacity of a basic model reported in accordance with paragraph (b)(2) of this section shall be the mean of the measured clothes container capacity, C, of all tested units of the basic model.
- (4)The remaining moisture content (RMC) of a basic model reported in accordance with paragraph (b)(2) of this section shall be the mean of the final RMC value measured for all tested units of the basic model.
- (b)Certification reports.
- (1)The requirements of § 429.12 are applicable to residential clothes washers; and
- (2)Pursuant to § 429.12(b)(13), a certification report shall contain the following public product-specific information:
- (i)For residential clothes washers tested in accordance with appendix J1: The modified energy factor (MEF) in cubic feet per kilowatt hour per cycle (cu ft/kWh/cycle), the capacity in cubic feet (cu ft), the corrected remaining moisture content (RMC) expressed as a percentage, and, for standard-size residential clothes washers, a water factor (WF) in gallons per cycle per cubic foot (gal/cycle/cu ft).
- (ii)For residential clothes washers tested in accordance with appendix J2: The integrated modified energy factor (IMEF) in cu ft/kWh/cycle, the integrated water factor (IWF) in gal/cycle/cu ft, the capacity in cu ft, the corrected remaining moisture content (RMC) expressed as a percentage, and the type of loading (top-loading or front-loading).
- (3)Pursuant to § 429.12(b)(13), a certification report must include the following additional product-specific information: A list of all cycle selections comprising the complete energy test cycle for each basic model.
- (c)Reported values. Values reported pursuant to this subsection must be rounded as follows: MEF and IMEF to the nearest 0.01 cu ft/kWh/cycle; WF and IWF to the nearest 0.1 gal/cycle/cu ft; RMC to the nearest 0.1 percentage point; and clothes container capacity to the nearest 0.1 cu ft.
Or,
Or,