10 CFR §71.33
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
The application must include a description of the proposed package in sufficient detail to identify the package accurately and provide a sufficient basis for evaluation of the package. The description must include—
- (a)With respect to the packaging—
- (1)Classification as Type B(U), Type B(M), or fissile material packaging;
- (2)Gross weight;
- (3)Model number;
- (4)Identification of the containment system;
- (5)Specific materials of construction, weights, dimensions, and fabrication methods of—
- (i)Receptacles;
- (ii)Materials specifically used as nonfissile neutron absorbers or moderators;
- (iii)Internal and external structures supporting or protecting receptacles;
- (iv)Valves, sampling ports, lifting devices, and tie-down devices; and
- (v)Structural and mechanical means for the transfer and dissipation of heat; and
- (6)Identification and volumes of any receptacles containing coolant.
- (b)With respect to the contents of the package—
- (1)Identification and maximum radioactivity of radioactive constituents;
- (2)Identification and maximum quantities of fissile constituents;
- (3)Chemical and physical form;
- (4)Extent of reflection, the amount and identity of nonfissile materials used as neutron absorbers or moderators, and the atomic ratio of moderator to fissile constituents;
- (5)Maximum normal operating pressure;
- (6)Maximum weight;
- (7)Maximum amount of decay heat; and
- (8)Identification and volumes of any coolants.