- (a)Protective devices, such as fuses or circuit breakers, must be installed in each electrical circuit other than—
- (b)A protective device for a circuit essential to flight safety may not be used to protect any other circuit.
- (c)Each resettable circuit protective device (“trip free” device in which the tripping mechanism cannot be overridden by the operating control) must be designed so that—
- (d)If the ability to reset a circuit breaker or replace a fuse is essential to safety in flight, that circuit breaker or fuse must be located and identified so that it can be readily reset or replaced in flight.
- (e)If fuses are used, there must be one spare of each rating, or 50 percent spare fuses of each rating, whichever is greater.