StacksVerified U.S. regulatory reference

14 CFR §29.1105

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov
If induction system screens are used—
  1. (a)Each screen must be upstream of the carburetor;
  2. (b)No screen may be in any part of the induction system that is the only passage through which air can reach the engine, unless it can be deiced by heated air;
  3. (c)No screen may be deiced by alcohol alone; and
  4. (d)It must be impossible for fuel to strike any screen.