14 CFR §29.625
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
For each fitting (part or terminal used to join one structural member to another) the following apply:
- (a)For each fitting whose strength is not proven by limit and ultimate load tests in which actual stress conditions are simulated in the fitting and surrounding structures, a fitting factor of at least 1.15 must be applied to each part of—
- (b)No fitting factor need be used—
- (c)For each integral fitting, the part must be treated as a fitting up to the point at which the section properties become typical of the member.
- (d)Each seat, berth, litter, safety belt, and harness attachment to the structure must be shown by analysis, tests, or both, to be able to withstand the inertia forces prescribed in § 29.561(b)(3) multiplied by a fitting factor of 1.33.