14 CFR §29.695
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)If a power boost or power-operated control system is used, an alternate system must be immediately available that allows continued safe flight and landing in the event of—
- (b)Each alternate system may be a duplicate power portion or a manually operated mechanical system. The power portion includes the power source (such as hydrualic pumps), and such items as valves, lines, and actuators.
- (c)The failure of mechanical parts (such as piston rods and links), and the jamming of power cylinders, must be considered unless they are extremely improbable.