14 CFR §29.851
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Hand fire extinguishers. For hand fire extinguishers the following apply:
- (1)Each hand fire extinguisher must be approved.
- (2)The kinds and quantities of each extinguishing agent used must be appropriate to the kinds of fires likely to occur where that agent is used.
- (3)Each extinguisher for use in a personnel compartment must be designed to minimize the hazard of toxic gas concentrations.
- (b)Built-in fire extinguishers. If a built-in fire extinguishing system is required—