14 CFR §31.21
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
Strength requirements are specified in terms of limit loads, that are the maximum load to be expected in service, and ultimate loads, that are limit loads multiplied by prescribed factors of safety. Unless otherwise specified, all prescribed loads are limit loads.