30 CFR §15.7
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)An approved explosive or sheathed explosive unit shall be marketed only under the brand or trade name specified in the approval.
- (b)The wrapper of each cartridge and each case of approved explosives shall be legibly labeled with the following: the brand or trade name, “MSHA Approved Explosive”, the test detonator strength, and the minimum product firing temperature.
- (c)The outer covering of each sheathed explosive unit and each case of approved sheathed explosive units shall be legibly labeled with the following: the brand or trade name, “MSHA Approved Sheathed Explosive Unit”, the test detonator strength, and the minimum product firing temperature.