30 CFR §18.25
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Insulating materials that give off flammable or explosive gases when decomposed electrically shall not be used within enclosures where the materials are subjected to destructive electrical action.
- (b)Parts coated or impregnated with insulating materials shall be heat-treated to remove any combustible solvent(s) before assembly in an explosion-proof enclosure. Air-drying insulating materials are excepted.