30 CFR §18.60
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
An inspection of each electrical component shall include the following:
- (a)A detailed check of parts against the drawings submitted by the applicant to determine that: (1) The parts and drawings coincide; and (2) the minimum requirements stated in this part have been met with respect to materials, dimensions, configuration, workmanship, and adequacy of drawings and specifications.
- (b)Exact measurement of joints, journal bearings, and other flame-arresting paths.
- (c)Examination for unnecessary through holes.
- (d)Examination for adequacy of lead-entrance design and construction.
- (e)Examination for adequacy of electrical insulation and clearances between live parts and between live parts and the enclosure.
- (f)Examination for weaknesses in welds and flaws in castings.
- (g)Examination for distortion of enclosures before tests.
- (h)Examination for adequacy of fastenings, including size, spacing, security, and possibility of bottoming.