30 CFR §250.1152
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)When you conduct well tests you must:
- (1)Recover fluid from the well completion equivalent to the amount of fluid introduced into the formation during completion, recompletion, reworking, or treatment operations before you start a well test;
- (2)Produce the well completion under stabilized rate conditions for at least 6 consecutive hours before beginning the test period;
- (3)Conduct the test for at least 4 consecutive hours;
- (4)Adjust measured gas volumes to the standard conditions of 14.73 pounds per square inch absolute (psia) and 60 °F for all tests; and
- (5)Use measured specific gravity values to calculate gas volumes.
- (b)You may request approval from the Regional Supervisor to conduct a well test using alternative procedures if you can demonstrate test reliability under those procedures.
- (c)The Regional Supervisor may also require you to conduct the following tests and complete them within a specified time period:
- (d)A BSEE representative may witness any well test. Upon request, you must provide advance notice to the Regional Supervisor of the times and dates of well tests.