30 CFR §57.19024
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
Unless damage or deterioration is removed by cutoff, wire ropes shall be removed from service when any of the following conditions occurs:
- (a)The number of broken wires within a rope lay length, excluding filler wires, exceeds either—
- (b)On a regular lay rope, more than one broken wire in the valley between strands in one rope lay length.
- (c)A loss of more than one-third of the original diameter of the outer wires.
- (d)Rope deterioration from corrosion.
- (e)Distortion of the rope structure.
- (f)Heat damage from any source.
- (g)Diameter reduction due to wear that exceeds six percent of the baseline diameter measurement.
- (h)Loss of more than ten percent of rope strength as determined by nondestructive testing.