30 CFR §57.6160
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Main facilities used to store explosive material underground shall be located—
- (1)In stable or supported ground;
- (2)So that a fire or explosion in the storage facilities will not prevent escape from the mine, or cause detonation of the contents of another storage facility;
- (3)Out of the line of blasts, and protected from vehicular traffic, except that accessing the facility;
- (4)At least 200 feet from work places or shafts;
- (5)At least 50 feet from electric substations;
- (6)A safe distance from trolley wires; and
- (7)At least 25 feet from detonator storage facilities.
- (b)Main facilities used to store explosive material underground shall be—
- (1)Posted with warning signs that indicate the contents and are visible from any approach;
- (2)Used exclusively for the storage of explosive material and necessary equipment associated with explosive material storage and delivery:
- (3)Kept clean, suitably dry, and orderly;
- (4)Provided with unobstructed ventilation openings;
- (5)Kept securely locked unless all access to the mine is either locked or attended; and
- (6)Unlighted or lighted only with devices that do not create a fire or explosion hazard and which are specifically designed for use in magazines.
- (c)Electrical switches and outlets shall be located outside the facility.