30 CFR §7.507
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Each refuge alternative shall have an air-monitoring component that provides persons inside with the ability to determine the concentrations of carbon dioxide, carbon monoxide, oxygen, and methane, inside and outside the structure, including the airlock.
- (b)Refuge alternatives designed for use in mines with a history of harmful gases, other than carbon monoxide, carbon dioxide, and methane, shall be equipped to measure the harmful gases' concentrations.
- (c)The air-monitoring component shall be inspected or tested and the test results shall be included in the application.
- (d)The air-monitoring component shall meet the following:
- (1)The total measurement error, including the cross-sensitivity to other gases, shall not exceed ±10 percent of the reading, except as specified in the approval.
- (2)The measurement error limits shall not be exceeded after start-up, after 8 hours of continuous operation, after 96 hours of storage, and after exposure to atmospheres with a carbon monoxide concentration of 999 ppm (full-scale), a carbon dioxide concentration of 3 percent, and full-scale concentrations of other gases.
- (3)Calibration gas values shall be traceable to the National Institute for Standards and Technology (NIST) “Standard Reference Materials” (SRMs).
- (4)The analytical accuracy of the calibration gas and span gas values shall be within 2.0 percent of NIST gas standards.
- (5)The detectors shall be capable of being kept fully charged and ready for immediate use.