- (a)Electric equipment must be permissible and maintained in a permissible condition when such equipment is located within 150 feet of pillar workings or longwall faces.
- (b)Electric conductors and cables installed in or in by the last open crosscut or within 150 feet of pillar workings or longwall faces must be—
- (1)Shielded high-voltage cables supplying power to permissible longwall equipment;
- (2)Interconnecting conductors and cables of permissible longwall equipment;
- (3)Conductors and cables of intrinsically safe circuits; and
- (4)Cables and conductors supplying power to low- and medium-voltage permissible equipment.
- (5)Shielded high-voltage cables supplying power to permissible continuous mining machines.