30 CFR §75.1714-4
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Additional SCSRs in work places. In addition to the requirements in §§ 75.1714, 75.1714-1, 75.1714-2, and 75.1714-3 of this part, the mine operator shall provide the following:
- (1)At least one additional SCSR, which provides protection for a period of one hour or longer, for each person at a fixed underground work location.
- (2)Additional SCSRs along the normal travel routes for pumpers, examiners, and other persons who do not have a fixed work location to be stored at a distance an average miner could walk in 30 minutes. The SCSR storage locations shall be determined by using one of the methods found under paragraph (c)(2) of this section.
- (b)Additional SCSRs on mantrips. If a mantrip or mobile equipment is used to enter or exit the mine, at least one additional SCSR, which provides protection for a period of one hour or longer, shall be available for each person who uses such transportation from portal to portal.
- (c)Additional SCSRs in escapeways. When each person underground cannot safely evacuate the mine within 30 minutes, the mine operator shall provide additional SCSRs stored in each required escapeway.
- (1)Each storage location shall contain at least one SCSR, which provides protection for a period of one hour or longer, for every person who will be inby that location.
- (2)Storage locations shall be spaced along each escapeway at 30-minute travel distances no greater than the distances determined by—
- (i)Calculating the distance an average miner walks in 30 minutes by using the time necessary for each miner in a sample of typical miners to walk a typical length of each escapeway; or
- (ii)Using the SCSR storage location spacing specified in the following table, except for escapeways with grades over 5 percent.
- (d)Additional SCSRs in hardened rooms. As an alternative to providing SCSR storage locations in each escapeway, the mine operator may store SCSRs in a hardened room located between adjacent escapeways.
- (1)The hardened room shall be designed and constructed to the same explosion force criteria as seals.
- (2)The hardened room shall include a means to provide independent, positive pressure ventilation from the surface during an emergency.
- (3)The District Manager shall approve the design and construction of hardened rooms in the ventilation plan.
- (4)These SCSR storage locations shall be spaced in accordance with paragraph (c) of this section.
- (e)Storage location accessibility. All SCSRs required under this section shall be stored according to the manufacturers' instructions, in conspicuous locations readily accessible by each person in the mine.
- (f)Storage location signs. A sign made of reflective material with the words “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each storage location. Direction signs made of a reflective material shall be posted leading to each storage location.