Unless damage or deterioration is removed by cutoff, wire ropes shall be removed from service when any of the following conditions occurs:
- (a)The number of broken wires within a rope lay length, excluding filler wires, exceeds either—
- (b)On a regular lay rope, more than one broken wire in the valley between strands in one rope lay length;
- (c)A loss of more than one-third of the original diameter of the outer wires;
- (d)Rope deterioration from corrosion;
- (e)Distortion of the rope structure;
- (f)Heat damage from any source;
- (g)Diameter reduction due to wear that exceeds six percent of the baseline diameter measurement; or
- (h)Loss of more than ten percent of rope strength as determined by nondestructive testing.