- (a)Ladders shall be of substantial construction and maintained in good condition.
- (b)Wooden members of ladders shall not be painted.
- (c)Steep or vertical ladders which are used regularly at fixed locations shall be anchored securely and provided with backguards extending from a point not more than 7 feet from the bottom of the ladder to the top of the ladder.
- (d)Fixed ladders shall not incline backwards at any point unless provided with backguards.
- (e)Fixed ladders shall be anchored securely and installed to provide at least 3 inches of toe clearance.
- (f)Fixed ladders shall project at least 3 feet above landings, or substantial handholds shall be provided above the landings.