Each Operations Manual must contain—
- (a)A description of each liquid-transfer system and vapor transfer system, including each mooring area, transfer connection, and (where installed) control room, and a diagram of the piping and electrical systems;
- (b)The duties of each person assigned to transfers;
- (c)The maximum relief-valve setting or MAWP of the transfer system;
- (d)The telephone numbers of supervisors, persons in charge of transfers for the facility, persons on watch in the marine transfer area for LHG, and security personnel of the facility;
- (e)A description for each security system provided for the transfer area;
- (f)A description of the training programs established under § 127.1302;
- (g)The procedures to follow for security violations; and
- (h)For each LHG handled, the procedures for transfer that include—