33 CFR §127.1315
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
Before each transfer, the person in charge of transfer for the facility must—
- (a)Inspect piping and equipment within the marine transfer area for LHG to be used for transfer and ensure that it meets the requirements in this part;
- (b)Determine the contents, pressure, temperature, and capacity of each storage tank to or from which LHG will be transferred, to ensure that it is safe for transfer;
- (c)Confer with the person in charge of transfer aboard the vessel, to review and agree on—
- (d)Ensure that the vessel is securely moored and that the transfer connections allow it to move to the limits of its moorings without placing a strain on the piping, hose, or loading arm used for transfer;
- (e)Ensure that each part of the transfer system is aligned to allow the flow of LHG to the desired place;
- (f)Ensure the display of the warning signs required by § 127.1113;
- (g)Ensure that the requirements of this part concerning smoking and fire protection are met;
- (h)Ensure that qualified personnel are on duty in accordance with the examined Operations Manual and §§ 127.1301 and 127.1302; and
- (i)Test the following to determine that they are operable:
- (1)The communication system required by § 127.1111.
- (2)The gas detectors required by § 127.1203.