33 CFR §158.240
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
The reception facility that services oceangoing ships using a ship repair yard must have a capacity for receiving—
- (a)An amount of ballast from bunker tanks, and the wash water and oil residue from the cleaning of bunker tanks and oil residue (sludge) tanks, equal to 8 percent of the bunker capacity of the largest oceangoing ship serviced;
- (b)An amount of solid oil cargo residues from cargo tanks equal to 0.1 percent of the deadweight tonnage of the largest oceangoing tanker serviced;
- (c)An amount of ballast water containing oily mixtures and wash water from in-port tank washing equal to—
- (d)An amount of liquid oil cargo residue based on the following percentages of deadweight tonnage of the largest oceangoing tanker serviced: