Each fuel line from the fuel tank to the fuel inlet connection on the carburetor must:
- (a)Be above the level of the tank top; or
- (b)Have an anti-siphon device or an electrically operated fuel stop valve:
- (c)Provided that the fuel tank top is below the level of the carburetor inlet, be metallic fuel lines meeting the construction requirements of § 183.538 or “USCG Type A1” hose, with one or two manual shutoff valves installed as follows:
- (1)Directly at the fuel tank connection arranged to be readily accessible for operation from outside of the compartment, and
- (2)If the length of fuel line from the tank outlet to the engine inlet is greater than 12 feet, a manual shutoff valve shall be installed at the fuel inlet connection to the engine.