- (a)Each compartment in a boat that has a permanently installed gasoline engine with a cranking motor must:
- (b)Each exhaust blower or combination of blowers must be rated at an air flow capacity not less than that computed by the formulas given in Table 183.610, Column 2. Blower rating must be determined according to AMCA Standard 210-74, Figure 12, or UL Standard 1128.
- (c)Each exhaust blower system required by paragraph (a)(2) of this section must exhaust air from the boat at a rate which meets the requirements of Table 183.610, Column 3 when the engine is not operating.
- (d)Each intake duct for an exhaust blower must be in the lower one-third of the compartment and above the normal level of accumulated bilge water.
- (e)More than one exhaust blower may be used in combination to meet the requirements of this section.
- (f)Each boat that is required to have an exhaust blower must have a label that: