- (a)The gas analysis report must contain the following information:
- (1)The information required in § 3170.7(g) of this part;
- (2)The date and time that the sample for spot samples was taken or, for composite samples, the date the cylinder was installed and the date the cylinder was removed;
- (3)The date and time of the analysis;
- (4)For spot samples, the effective date, if other than the date of sampling;
- (5)For composite samples, the effective start and end date;
- (6)The name of the laboratory where the analysis was performed;
- (7)The device used for analysis (i.e., GC, calorimeter, or mass spectrometer);
- (8)The make and model of analyzer;
- (9)The date of last calibration or verification of the analyzer;
- (10)The flowing temperature at the time of sampling;
- (11)The flowing pressure at the time of sampling, including units of measure (psia or psig);
- (12)The flow rate at the time of sampling;
- (13)The ambient air temperature at the time of sampling;
- (14)Whether or not heat trace or any other method of heating was used;
- (15)The type of sample (i.e., spot-cylinder, spot-portable GC, composite);
- (16)The sampling method if spot-cylinder (e.g., fill and empty, helium pop);
- (17)A list of the components of the gas tested;
- (18)The un-normalized mole percents of the components tested, including a summation of those mole percents;
- (19)The normalized mole percent of each component tested, including a summation of those mole percents;
- (20)The ideal heating value (Btu/scf);
- (21)The real heating value (Btu/scf), dry basis;
- (22)The hexane+ split, if applicable;
- (23)The pressure base and temperature base;
- (24)The relative density; and
- (25)The name of the company obtaining the gas sample.
- (b)Components that are listed on the analysis report, but not tested, must be annotated as such.
- (c)The heating value and relative density must be calculated under API 14.5 (incorporated by reference, see § 3175.30).
- (d)The base supercompressibility must be calculated under AGA Report No. 8 (incorporated by reference, see § 3175.30).
- (e)The operator must submit all gas analysis reports to the BLM within 15 days of the due date for the sample as specified in § 3175.115.
- (f)Unless a variance is granted, the operator must submit all gas analysis reports and other required related information electronically through the GARVS. The BLM will grant a variance to the electronic-submission requirement only in cases where the operator demonstrates that it is a small business, as defined by the U.S. Small Business Administration, and does not have access to the Internet.