43 CFR §3175.91
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Gauge lines connecting the pressure taps to the mechanical recorder must:
- (1)Have a nominal diameter of not less than 3/8 inch, including ports and valves;
- (2)Be sloped upwards from the pressure taps at a minimum pitch of 1 inch per foot of length with no visible sag;
- (3)Be the same internal diameter along their entire length;
- (4)Not include tees, except for the static-pressure line;
- (5)Not be connected to more than one differential-pressure bellows and static-pressure element, or to any other device; and
- (6)Be no longer than 6 feet.
- (b)The differential-pressure pen must record at a minimum reading of 10 percent of the differential-pressure-bellows range for the majority of the flowing period. This requirement does not apply to inverted charts.
- (c)The flowing temperature of the gas must be continuously recorded and used in the volume calculations under § 3175.94(a)(1).
- (d)The following information must be maintained at the FMP in a legible condition, in compliance with § 3170.7(g) of this part, and accessible to the AO at all times:
- (1)Differential-pressure-bellows range;
- (2)Static-pressure-element range;
- (3)Temperature-element range;
- (4)Relative density (specific gravity) of the gas;
- (5)Static-pressure units of measure (psia or psig);
- (6)Meter elevation;
- (7)Meter-tube inside diameter;
- (8)Primary device type;
- (9)Orifice-bore or other primary-device dimensions necessary for device verification, Beta- or area-ratio determination, and gas-volume calculation;
- (10)Make, model, and location of approved isolating flow conditioners, if used;
- (11)Location of the downstream end of 19-tube-bundle flow straighteners, if used;
- (12)Date of last primary-device inspection; and
- (13)Date of last meter verification.
- (e)The differential pressure, static pressure, and flowing temperature elements must be operated between the lower- and upper-calibrated limits of the respective elements.