43 CFR §3274.11
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
Submit a completed and signed commercial permit form, to BLM, containing the following information:
- (a)The design specifications, and the inspection and calibration schedule of production, injection, and royalty meters;
- (b)A schematic diagram of the utilization site or individual well, showing the location of each production and royalty meter. If the sales point is located off the utilization site, give us a generalized schematic diagram of the electrical transmission or pipeline system, including meter locations;
- (c)A copy of the sales contract for the sale and/or utilization of geothermal resources;
- (d)A description and analysis of reservoir, production, and injection characteristics, including the flow rates, temperatures, and pressures of each production and injection well;
- (e)A schematic diagram of each production and injection well showing the wellhead configuration, including meters;
- (f)A schematic flow diagram of the utilization facility, including interconnections with other facilities, if applicable;
- (g)A description of the utilization process in sufficient detail to enable BLM to determine whether the resource will be utilized in a manner consistent with law and regulations;
- (h)The planned safety provisions for emergency shutdown to protect public health, safety, property, and the environment. This should include a schedule for the testing and maintenance of safety devices;
- (i)The environmental and operational parameters that will be monitored during the operation of the facility and/or well(s); and
- (j)Any additional information or data that we may require.