CFR › Title 47 › Part 95 › §95.320547 CFR §95.3205Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗Copy link(a)C-V2X OBUs must comply with the following out-of-band emissions limits. Conducted emissions limits measured at the antenna input shall not exceed:(1)−16 dBm/100 kHz within ±1 megahertz of the band edges;(2)−13 dBm/MHz within ±1 megahertz to ±5 megahertz of the band edges;(3)−16 dBm/MHz within ±5 megahertz to ±30 megahertz of the band edges; and(4)−28 dBm/MHz beyond 30 megahertz from the band edges.