49 CFR §179.200-15
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Manway covers must be of approved type.
- (b)Manway covers shall be designed to provide a secure closure of the manway.
- (c)Manway covers must be of approved cast, forged, or fabricated metals. Malleable iron, if used, must comply with ASTM A 47 (IBR, see § 171.7 of this subchapter), Grade 35018. Cast iron manway covers must not be used.
- (d)All joints between manway covers and their seats shall be made tight against leakage of vapor and liquid by use of gaskets of suitable material.
- (e)For other manway cover requirements see § 179.201-1.