49 CFR §179.300-18
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)To certify that the tank complies with all specification requirements, each tank shall be plainly and permanently stamped in letters and figures 3/8 inch high into the metal of valve end chime as follows:
- (1)DOT Specification number.
- (2)Material and cladding material if any (immediately below the specification number).
- (3)Owner's or builder's identifying symbol and serial number (immediately below the material identification). The symbol shall be registered with the Bureau of Explosives, duplications are not authorized.
- (4)Inspector's official mark (immediately below the owner's or builder's symbol).
- (5)Date of original tank test (month and year, such as 1-64 for January 1964). This should be so placed that dates of subsequent tests may easily be added thereto.
- (6)Water capacity—0000 pounds.
- (b)A copy of the above stamping in letters and figures of the prescribed size stamped on a brass plate secured to one of the tank heads is authorized.