49 CFR §192.711
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Temporary repairs. Each operator must take immediate temporary measures to protect the public whenever:
- (b)Permanent repairs. An operator must make permanent repairs on its pipeline system according to the following:
- (1)
- (i)Non-integrity management repairs for gathering lines and offshore transmission lines: For gathering lines subject to this section in accordance with § 192.9 and for offshore transmission lines, an operator must make permanent repairs as soon as feasible.
- (ii)Non-integrity management repairs for onshore transmission lines: Except for gathering lines exempted from this section in accordance with § 192.9 and offshore transmission lines, after May 24, 2023, whenever an operator discovers any condition that could adversely affect the safe operation of a pipeline segment not covered by an integrity management program under subpart O of this part, it must correct the condition as prescribed in § 192.714.
- (2)Integrity management repairs: When an operator discovers a condition on a pipeline covered under Subpart O-Gas Transmission Pipeline Integrity Management, the operator must remediate the condition as prescribed by § 192.933(d).
- (1)
- (c)Welded patch. Except as provided in § 192.717(b)(3), no operator may use a welded patch as a means of repair.