49 CFR §195.559
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
Coating material for external corrosion control under § 195.557 must—
- (a)Be designed to mitigate corrosion of the buried or submerged pipeline;
- (b)Have sufficient adhesion to the metal surface to prevent under film migration of moisture;
- (c)Be sufficiently ductile to resist cracking;
- (d)Have enough strength to resist damage due to handling and soil stress;
- (e)Support any supplemental cathodic protection; and
- (f)If the coating is an insulating type, have low moisture absorption and provide high electrical resistance.