  1. (a)General. Except as provided in paragraph (b) of this section, each circuit that affects the proper functioning of a highway-rail grade crossing warning system shall be kept free of any ground or combination of grounds that will permit a current flow of 75 percent or more of the value necessary to retain a permissive state of a safety appliance.
  2. (b)Exception. Paragraph (a) of this section does not apply to the following:
    1. (1)Circuits that include track rail;
    2. (2)Alternating current power distribution circuits that are grounded in the interest of safety;
    3. (3)Circuitry internal to microprocessor-based appliances;
    4. (4)Circuitry internal to semiconductor-based memory; and
    5. (5)Common return wires of grounded common return single break circuits.