49 CFR §234.213
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)General. Except as provided in paragraph (b) of this section, each circuit that affects the proper functioning of a highway-rail grade crossing warning system shall be kept free of any ground or combination of grounds that will permit a current flow of 75 percent or more of the value necessary to retain a permissive state of a safety appliance.
- (b)Exception. Paragraph (a) of this section does not apply to the following:
- (1)Circuits that include track rail;
- (2)Alternating current power distribution circuits that are grounded in the interest of safety;
- (3)Circuitry internal to microprocessor-based appliances;
- (4)Circuitry internal to semiconductor-based memory; and
- (5)Common return wires of grounded common return single break circuits.