StacksVerified U.S. regulatory reference

49 CFR §237.33

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov
Each bridge management program adopted in compliance with this part shall include, as a minimum, the following:
  1. (a)An accurate inventory of railroad bridges, which shall include a unique identifier for each bridge, its location, configuration, type of construction, number of spans, span lengths, and all other information necessary to provide for the management of bridge safety;
  2. (b)A record of the safe load capacity of each bridge;
  3. (c)A provision to obtain and maintain the design documents of each bridge if available, and to document all repairs, modifications, and inspections of each bridge; and
  4. (d)A bridge inspection program covering as a minimum:
    1. (1)Inspection personnel safety considerations;
    2. (2)Types of inspection including required detail;
    3. (3)Definitions of defect levels along with associated condition codes if condition codes are used;
    4. (4)The method of documenting inspections including standard forms or formats;
    5. (5)Structure type and component nomenclature; and
    6. (6)Numbering or identification protocol for substructure units, spans, and individual components.