Prior to June 21, 2016, manufacturers must make any representations with respect to the energy use or efficiency of ceiling fan light kits with pin-based sockets for fluorescent lamps in accordance with the results of testing pursuant to this Appendix V or the procedures in Appendix V as it appeared at 10 CFR part 430, subpart B, Appendix V, in the 10 CFR parts 200 to 499 edition revised as of January 1, 2015. On or after June 21, 2016, manufacturers must make any representations with respect to energy use or efficiency of ceiling fan light kits with pin-based sockets for fluorescent lamps in accordance with the results of testing pursuant to this appendix to demonstrate compliance with the energy conservation standards at 10 CFR 430.32(s)(3).
Alternatively, manufacturers may make representations based on testing in accordance with appendix V1 to this subpart, provided that such representations demonstrate compliance with the amended energy conservation standards. Manufacturers must make all representations with respect to energy use or efficiency in accordance with whichever version is selected for testing.
1. Scope: This appendix contains test requirements to measure the energy performance of ceiling fan light kits (CFLKs) with pin-based sockets that are packaged with fluorescent lamps.
2. Definitions
2.1. Input power means the measured total power used by all lamp(s) and ballast(s) of the CFLK during operation, expressed in watts (W) and measured using the lamp and ballast packaged with the CFLK.
2.2. Lamp ballast platform means a pairing of one ballast with one or more lamps that can operate simultaneously on that ballast. Each unique combination of manufacturer, basic model numbers of the ballast and lamp(s), and the quantity of lamps that operate on the ballast, corresponds to a unique platform.
2.3. Lamp lumens means a measurement of lumen output or luminous flux measured using the lamps and ballasts shipped with the CFLK, expressed in lumens.
2.4. System efficacy means the ratio of measured lamp lumens to measured input power, expressed in lumens per watt, and is determined for each unique lamp ballast platform packaged with the CFLK.
3. Test Apparatus and General Instructions:
The test apparatus and instructions for testing pin-based fluorescent lamps packaged with ceiling fan light kits that have pin-based sockets must conform to the following requirements:
Any lamp satisfying this description: | must be tested on the lamp ballast platform packaged with the CFLK in accordance with the requirements of: |
Compact fluorescent lamp | sections 4-6 of IES LM-66-14 (incorporated by reference, see §430.3) |
Any other fluorescent lamp | sections 4-7 of IES LM-9-09 (incorporated by reference, see §430.3) |
4. Test Measurement and Calculations:
Measure system efficacy as follows and express the result in lumens per watt:
Lamp type | Method |
---|---|
Compact fluorescent lamp | Measure system efficacy according to section 6 of IES LM-66-14 (incorporated by reference; see §430.3). Use of a goniophotometer is not permitted. |
Any other fluorescent lamp | Measure system efficacy according to section 7 of IES LM-9-09 (incorporated by reference; see §430.3). Use of a goniophotometer is not permitted. |
[80 FR 80226, Dec. 24, 2015]