(a) Determination of represented value. Manufacturers must determine the represented value, which includes the certified rating, for each basic model of compressor either by testing in conjunction with the applicable sampling provisions or by applying an AEDM.

(1) Units to be tested.

(i) If the represented value is determined through testing, the general requirements of §429.11 apply; and

(ii) For each basic model selected for testing, a sample of sufficient size must be randomly selected and tested to ensure that—

(A) Measures of energy efficiency. Any represented value of the full- or part-load package isentropic efficiency or other measure of energy efficiency of a basic model for which customers would favor higher values is less than or equal to the lower of:

(1) The mean of the sample, where:

eCFR graphic er04ja17.007.gif

And x̅ is the sample mean; n is the number of samples; and xi is the measured value for the ith sample; or,

(2) The lower 95 percent confidence limit (LCL) of the true mean divided by 0.95, where:

eCFR graphic er04ja17.008.gif

And x̅ is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.95 is the t statistic for a 95 percent one-tailed confidence interval with n−1 degrees of freedom (from appendix A of this subpart); and

(B) Package specific power. The representative value(s) of package specific power of a basic model must be the mean of the package specific power measurement(s) for each tested unit of the basic model.

(2) Alternative efficiency determination methods. In lieu of testing, any represented value of efficiency, consumption, or other non-energy metrics listed in paragraph (a)(3) of this section for a basic model may be determined through the application of an AEDM pursuant to the requirements of §429.70 and the provisions of this section, where:

(i) Any represented values of package isentropic efficiency or other measure of energy consumption of a basic model for which customers would favor higher values must be less than or equal to the output of the AEDM; and

(ii) Any represented values of package specific power, pressure ratio at full-load operating pressure, full-load actual volume flow rate, or full-load operating pressure must be the output of the AEDM corresponding to the represented value of package isentropic efficiency determined in paragraph (a)(2)(i) of this section.

(3) Representations of non-energy metrics—(i) Full-load actual volume flow rate. The representative value of full-load actual volume flow rate of a basic model must be either—

(A) The mean of the full-load actual volume flow rate for the units in the sample; or

(B) As determined through the application of an AEDM pursuant to the requirements of §429.70.

(ii) Full-load operating pressure. The representative value of full-load operating pressure of a basic model must be less than or equal to the maximum full-flow operating pressure and greater than or equal to the lesser of—

(A) 90 percent of the maximum full-flow operating pressure; or

(B) 10 psig less than the maximum full-flow operating pressure, where the maximum full-flow operating pressure must either be determined as the mean of the maximum full-flow operating pressure values for the units in the sample or through the application of an AEDM pursuant to the requirements of §429.70.

(iii) Pressure ratio at full-load operating pressure. The representative value of pressure ratio at full-load operating pressure of a basic model must be either be determined as the mean of the pressure ratio at full-load operating pressure for the units in the sample or through the application of an AEDM pursuant to the requirements of §429.70.

(b) Certification reports.

(1) The requirements of §429.12 are applicable to compressors; and

(2) Pursuant to §429.12(b)(13), a certification report will include the following public product-specific information:

(i) Full-load package isentropic efficiency or part-load package isentropic efficiency, as applicable (dimensionless).

(ii) Full-load actual volume flow rate (in cubic feet per minute).

(iii) Compressor motor nominal horsepower (in horsepower).

(iv) Full-load operating pressure (in pounds per square inch, gauge).

(v) Maximum full-flow operating pressure (in pounds per square inch, gauge).

(vi) Pressure ratio at full-load operating pressure (dimensionless).

(vii) For any ancillary equipment that is installed for test, but is not part of the compressor package as distributed in commerce (per the requirements of 10 CFR part 431, subpart T, appendix A, section I(B)(4)), the following must be reported:

(A) A general description of the ancillary equipment, based on the list provided in the first column of Table 1 of 10 CFR part 431, subpart T, appendix A, section I(B)(4).

(B) The manufacturer of the ancillary equipment.

(C) The brand of the ancillary equipment (if different from the manufacturer).

(D) The model number of the ancillary equipment.

(E) The serial number of the ancillary equipment (if applicable).

(F) The following electrical characteristics, if applicable:

(1) Input Voltage.

(2) Number of Phases.

(3) Input Frequency.

(G) The following mechanical characteristics, if applicable:

(1) Size of any connections.

(2) Type of any connections.

(H) Installation instructions for the ancillary equipment, accompanied by photos that clearly illustrate the ancillary equipment, as installed on compresssor package. Instructions and photo(s) to be provided in portable document format (i.e., a PDF file).

[82 FR 1099, Jan. 4, 2017, as amended at 85 FR 1591, Jan. 10, 2020]