§ 1919.31 Proof tests—loose gear.
(a) Chains, rings, shackles and other loose gear (whether accessory to a machine or not) shall be tested with a proof load against the article equal to that shown in the following table:
Article of gear | Proof load |
---|---|
Chain, ring, hook, shackle or swivel | 100 percent in excess of the safe working load. |
Blocks: | |
Single sheave block | 300 percent in excess of the safe working load.1 |
Multiple sheave block with safe working load up to and including 20 tons | 100 percent in excess of the safe working load. |
Multiple sheave block with safe working load over 20 tons up to and including 40 tons | 20 tons in excess of the safe working load. |
Multiple sheave block with safe working load over 40 tons | 50 percent in excess of the safe working load. |
Pitched chains used with hand-operated blocks and rings, hooks, shackles or swivels permanently attached thereto | 50 percent in excess of the safe working load. |
Hand-operated blocks used with pitched chains and rings, hooks, shackles or swivels permanently attached thereto | 50 percent in excess of the safe working load. |
(b) In cases where persons accredited to carry out loose gear tests may be retained to conduct tests of special stevedoring gear as described in § 1918.61(b) of this chapter, which does not form part of a vessel's equipment, such tests shall adhere to the requirements set forth in § 1918.61(b) (1), (2), and (3) of this chapter.
(c) After being tested as required by paragraph (a) of this section, and before being taken into use, all chains, rings, hooks, shackles, blocks or other loose gear, except as noted in § 1919.32, shall be thoroughly examined, the sheaves and pins of the blocks being removed for this purpose, to determine whether any part has been injured or permanently deformed by the test. Shell bolt nuts shall be securely locked upon reassembly. Defective loose gear components shall be replaced before the certificate is issued.
(d) Any certificate relating to shackles, swivels or strength members of single-sheave blocks which have been restored to original dimensions by welding shall state this fact.