Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any liquid cane sugar refinery discharging both barometric condenser cooling water and other process waters shall meet the following limitations. The BOD5 limitation is determined by the addition of the net BOD5 attributed to the barometric condenser cooling water to that amount of BOD5 attributed to the treated process water. The TSS limitation is that amount of TSS attributed to the treated process water. Where the barometric condenser cooling water and process water streams are mixed and impossible to measure separately prior to discharge, the values should be considered net.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed— | |
Metric units (kilograms per 1,000 kg of melt) | ||
BOD5 | 0.78 | 0.32 |
TSS | .50 | .17 |
pH | (1) | (1) |
English units (pounds per ton of melt) | ||
BOD5 | 1.56 | 0.63 |
TSS | .99 | .33 |
pH | (1) | (1) |
1Within the range 6.0 to 9.0.
(b) Any liquid cane sugar refinery discharging barometric condenser cooling water only shall meet the following net limitations:
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed— | |
Metric units (kilograms per 1,000 kg of melt) | ||
BOD5 | 0.45 | 0.15 |
English units (pounds per ton of melt) | ||
BOD5 | 0.90 | 0.30 |
[39 FR 10526, Mar. 20, 1974, as amended at 60 FR 33950, June 29, 1995]