40 CFR § 415.654
Pretreatment standards for existing sources (PSES)
June 9, 2020
Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources (PSES):
Subpart BM—Cobalt Salts
Open Table
Pollutant or pollutant property | PSES effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Milligrams per liter (mg/l) | ||
Cobalt (T) | 3.6 | 1.4 |
Copper (T) | 3.3 | 1.0 |
Nickel (T) | 3.3 | 1.0 |
In cases where POTWs find it necessary to impose mass limitations, the following equivalent mass limitations are provided as an alternate: The limitations for cobalt (T), copper (T), and nickel (T), are the same as specified in §415.652.