40 CFR § 419.12
Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT)
June 9, 2020
CFR

(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Open Table
Pollutant or pollutant property BPT Effluent Limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed
Metric units (kilograms per 1,000 m3 of feedstock)
BOD5 22.7 12.0
TSS 15.8 10.1
COD1 117.0 60.3
Oil and grease 6.9 3.7
Phenolic compounds 0.168 0.076
Ammonia as N 2.81 1.27
Sulfide 0.149 0.068
Total chromium 0.345 0.20
Hexavalent chromium 0.028 0.012
pH (2) (2)
English units (pounds per 1,000 bbl of feedstock)
BOD5 8.0 4.25
TSS 5.6 3.6
COD1 41.2 21.3
Oil and grease 2.5 1.3
Phenolic compounds 0.060 0.027
Ammonia as N 0.99 0.45
Sulfide 0.053 0.024
Total chromium 0.122 0.071
Hexavalent chromium 0.01 0.0044
pH (2) (2)

1See footnote following table in §419.13(d).

2Within the range of 6.0 to 9.0.

(b) The limits set forth in paragraph (a) of this section are to be multiplied by the following factors to calculate the maximum for any one day and maximum average of daily values for thirty consecutive days.

(1) Size factor.

Open Table
1,000 bbl of feedstock per stream day Size factor
Less than 24.9 1.02
25.0 to 49.9 1.06
50.0 to 74.9 1.16
75.0 to 99.9 1.26
100 to 124.9 1.38
125.0 to 149.9 1.50
150.0 or greater 1.57

(2) Process factor.

Open Table
Process configuration Process factor
Less than 2.49 0.62
2.5 to 3.49 0.67
3.5 to 4.49 0.80
4.5 to 5.49 0.95
5.5 to 5.99 1.07
6.0 to 6.49 1.17
6.5 to 6.99 1.27
7.0 to 7.49 1.39
7.5 to 7.99 1.51
8.0 to 8.49 1.64
8.5 to 8.99 1.79
9.0 to 9.49 1.95
9.5 to 9.99 2.12
10.0 to 10.49 2.31
10.5 to 10.99 2.51
11.0 to 11.49 2.73
11.5 to 11.99 2.98
12.0 to 12.49 3.24
12.5 to 12.99 3.53
13.0 to 13.49 3.84
13.5 to 13.99 4.18
14.0 or greater 4.36

(3) See the comprehensive example Subpart D, §419.42(b)(3).

(c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best practicable control technology currently available, by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation allowed for ballast water flow, as kg/cu m (lb/M gal), shall be based on those ballast waters treated at the refinery.

Open Table
Pollutant or pollutant property BPT effluent limitations for ballast water
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed
Metric units (kilograms per cubic meter of flow)
BOD5 0.048 0.026
TSS 0.033 0.021
COD1 0.47 0.24
Oil and grease 0.015 0.008
pH (2) (2)
English units (pounds per 1,000 gal of flow)
BOD5 0.40 0.21
TSS 0.26 0.17
COD1 3.9 2.0
Oil and grease 0.126 0.067
pH (2) (2)

1See footnote following table in §419.13(d).

2Within the range of 6.0 to 9.0.

(d) The quantity and quality of pollutants or pollutant properties controlled by this paragraph, attributable to once-through cooling water, are excluded from the discharge allowed by paragraph (b) of this section. Once-through cooling water may be discharged with a total organic carbon concentration not to exceed 5 mg/l.

(e) Effluent limitations for contaminated runoff. The following effluent limitations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to contaminated runoff, which may be discharged after the application of the best practicable control technology currently available by a point source subject to this subpart.

(1) If wastewater consists solely of contaminated runoff and is not commingled or treated with process wastewater, it may be discharged if it does not exceed 15 mg/l oil and grease and 110 mg/l total organic carbon (TOC) based upon an analysis of any single grab or composite sample.

(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the concentrations listed in the following table:

Open Table
Pollutant or pollutant property BPT effluent limitations for contaminated runoff
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed
Metric units (kilograms per 1,000 m3 of flow)
BOD5 48. 26.
TSS 33. 21.
COD1 360. 180.
Oil and grease 15. 8.
Phenolic compounds (4AAP) 0.35 0.17
Total chromium 0.73 0.43
Hexavalent chromium 0.062 0.028
pH (2) (2)
English units (pounds per 1,000 gallons of flow)
BOD5 0.40 0.22
TSS 0.28 0.18
COD1 3.0 1.5
Oil and grease 0.13 0.067
Phenolic compounds (4AAP) 0.0029 0.0014
Total chromium 0.0060 0.0035
Hexavalent chromium 0.00052 0.00023
pH (2) (2)

1In any case in which the applicant can demonstrate that the chloride ion concentration in the effluent exceeds 1,000 mg/l (1,000 ppm), the permitting authority may substitute TOC as a parameter in lieu of COD. A TOC effluent limitation shall be based on effluent data from the particular refinery which correlates TOC to BOD5. If in the judgment of the permitting authority, adequate correlation data are not available, the effluent limitations for TOC shall be established at a ratio of 2.2 to 1 to the applicable effluent limitations for BOD5.

2Within the range of 6.0 to 9.0.

[47 FR 46446, Oct. 18, 1982, as amended at 50 FR 28522, 28523, July 12, 1985; 50 FR 32414, Aug. 12, 1985]


Tried the LawStack mobile app?

Join thousands and try LawStack mobile for FREE today.

  • Carry the law offline, wherever you go.
  • Download CFR, USC, rules, and state law to your mobile device.