40 CFR § 424.63
Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable
June 9, 2020
CFR

(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese after application of the best available technology economically achievable:

Open Table
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kg/kkg of product)
Manganese 0.678 0.339
Ammonia-N 6.778 3.389
English units (lb/1,000 lb of product)
Manganese 0.678 0.339
Ammonia-N 6.778 3.389

(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese dioxide after application of the best available technology economically achievable:

Open Table
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kg/kkg of product)
Manganese 0.176 0.088
Ammonia-N 1.762 .881
English units (lb/1,000 lb of product)
Manganese 0.176 0.088
Ammonia-N 1.762 .881

[44 FR 50745, Aug. 29, 1979]


Tried the LawStack mobile app?

Join thousands and try LawStack mobile for FREE today.

  • Carry the law offline, wherever you go.
  • Download CFR, USC, rules, and state law to your mobile device.