40 CFR § 426.125
Standards of performance for new sources
June 9, 2020
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
(a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following limitations with regard to the forming operations.
Open Table
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed— | |
Metric units (g/kkg of furnace pull) | ||
Oil | 90.0 | 45.0 |
TSS | 90.0 | 45.0 |
pH | (1) | (1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil | 0.09 | 0.045 |
TSS | 0.09 | 0.045 |
pH | (1) | (1) |
1Within the range 6.0 to 9.0.
(b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations.
Open Table
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed— | |
Metric units (g/kkg of product frosted) | ||
Fluoride | 104.0 | 52.0 |
Ammonia | 240.0 | 120.0 |
TSS | 80.0 | 40.0 |
pH | (1) | (1) |
English units (lb/1,000 lb of product frosted) | ||
Fluoride | 0.104 | 0.052 |
Ammonia | 0.24 | 0.12 |
TSS | 0.08 | 0.04 |
pH | (1) | (1) |
1Within the range 6.0 to 9.0.