40 CFR § 427.62
Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available
June 9, 2020
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Open Table
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed— | |
Metric units (kg/kkg of product) | ||
COD | 0.015 | 0.008 |
TSS | 0.010 | .006 |
pH | (1) | (1) |
English units (lb/ton of product) | ||
COD | 0.029 | 0.016 |
TSS | 0.020 | .012 |
pH | (1) | (1) |
1Within the range 6.0 to 9.0.
[39 FR 7527, Feb. 26, 1974, as amended at 60 FR 33961, June 29, 1995]