Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart where chlorophenolic-containing biocides are used must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT). Non-continuous dischargers shall not be subject to the maximum day mass limitations in kg/kkg (lb/1000 lb) but shall be subject to concentration limitations. Concentration limitations are only applicable to non-continuous dischargers. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides:
Subpart D
[BAT effluent limitations for dissolving sulfite pulp facilities where nitration, viscose, or cellophane pulps are produced]
Pollutant or pollutant property | Maximum for any 1 day | |
---|---|---|
Kg/kkg (or pounds per 1,000 lb) of product | Milligrams/liter | |
Pentachlorophenol | 0.0030 | (0.011)(66.0)/y |
Trichlorophenol | 0.019 | (0.068)(66.0)/y |
y = wastewater discharged in kgal per ton of product. |
Subpart D
[BAT effluent limitations for dissolving sulfite pulp facilities where acetate grade pulp is produced]
Pollutant or pollutant property | Maximum for any 1 day | |
---|---|---|
Kg/kkg (or pounds per 1,000 lb) of product | Milligrams/liter | |
Pentachlorophenol | 0.0033 | (0.011)(72.7)/y |
Trichlorophenol | 0.021 | (0.068)(72.7)/y |
y = wastewater discharged in kgal per ton of product. |