40 CFR § 430.92
Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT)
June 9, 2020
CFR

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT), except that non-continuous dischargers shall not be subject to the maximum day and average of 30 consecutive days limitations but shall be subject to annual average effluent limitations:

Subpart I

[BPT effluent limitations]

Open Table
Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days
BOD5 18.1   9.4   5.3  
TSS 24.05 12.95 7.12
pH (1) (1) (1)

1Within the range of 5.0 to 9.0 at all times.


Tried the LawStack mobile app?

Join thousands and try LawStack mobile for FREE today.

  • Carry the law offline, wherever you go.
  • Download CFR, USC, rules, and state law to your mobile device.