40 CFR § 437.21
Effluent limitations attainable by the application of the best practicable control technology currently available (BPT)
June 9, 2020
CFR

Except as provided in 40 CFR 125.30 through 125.32 or §437.20(b), any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BPT:

BPT Limitations

Open Table
Regulated
parameter
Maximum daily1 Maximum monthly avg.1
Conventional Parameters
O&G 127 38.0
pH (2) (2)
TSS 74.1 30.6
Metal Parameters
Arsenic 2.95 1.33
Cadmium 0.0172 0.0102
Chromium 0.746 0.323
Cobalt 56.4 18.8
Copper 0.500 0.242
Lead 0.350 0.160
Mercury 0.0172 0.00647
Tin 0.335 0.165
Zinc 8.26 4.50
Organic Parameters
Bis(2-ethylhexyl) phthalate 0.215 0.101
Butylbenzyl phthalate 0.188 0.0887
Carbazole 0.598 0.276
n-Decane 0.948 0.437
Fluoranthene 0.0537 0.0268
n-Octadecane 0.589 0.302

1mg/L (ppm).

2Within the range 6 to 9.

[65 FR 81300, Dec. 22, 2000, as amended at 68 FR 71023, Dec. 22, 2003]


Tried the LawStack mobile app?

Join thousands and try LawStack mobile for FREE today.

  • Carry the law offline, wherever you go.
  • Download CFR, USC, rules, and state law to your mobile device.