Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BPT:
(a)The limitation for BOD5 is the same as specified in §439.12(a).
(b) The limitation for TSS is the same as specified in §439.12(b).
(c) The limitations for COD are the same as specified in §439.12(c) and (d).
(d) The limitations for cyanide are the same as specified in §439.12(e), (f) and (g).
[63 FR 50431, Sept. 21, 1998, as amended at 68 FR 12273, Mar. 13, 2003]