(a) Except as provided in §403.7, any new source subject to this subpart that introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources:
(1) Subpart C—Open Formation—Dehydrated—PSNS.
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 2.15 | 1.02 |
Lead | 0.47 | 0.21 |
(2) Subpart C—Open Formation—Wet—PSNS.
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 0.067 | 0.032 |
Lead | 0.014 | 0.006 |
(3) Subpart C—Plate Soak—PSNS.
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 0.026 | 0.012 |
Lead | 0.005 | 0.002 |
(4) Subpart C—Battery Wash—(Detergent)—PSNS.
Pollutant or pollutant Property | Maximum for any 1 Day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 1.152 | 0.549 |
Lead | 0.252 | 0.117 |
(5) Subpart C—Direct Chill Lead Casting—PSNS.
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 0.000256 | 0.000122 |
Lead | 0.000056 | 0.000026 |
(6) Subpart C—Mold Release Formulation—PSNS.
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 0.007 | 0.0037 |
Lead | 0.0017 | 0.0008 |
(7) Subpart C—Truck Wash—PSNS.
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead in trucked batteries | ||
English units—pounds per 1,000,000 pounds of lead in trucked batteries | ||
Copper | 0.006 | 0.003 |
Lead | 0.001 | 0.0007 |
(8) Subpart C—Laundry—PSNS.
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 0.14 | 0.07 |
Lead | 0.03 | 0.01 |
(9) Subpart C—Miscellaneous Wastewater Streams—PSNS.
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 0.39 | 0.19 |
Lead | 0.085 | 0.039 |
(b) There shall be no discharge allowance for process wastewater pollutants from any battery manufacturing operations other than those battery manufacturing operations listed above.
[49 FR 9134, Mar. 9, 1984, as amended at 51 FR 30817, Aug. 28, 1986]