(a) NSPS for bis(2-ethylhexyl) phthalate are reserved.

(b) Any new source subject to this subpart must achieve performance standards (i.e., mass of pollutant discharged), which are calculated by multiplying the average process water usage flow rate for the contact cooling and heating water processes at a new source times the following pollutant concentrations:

Subpart A

[Contact cooling and heating water]

Open Table
Concentration used to calculate NSPS
Pollutant or pollutant property Maximum for any 1 day (mg/l)
BOD5 26
Oil and grease 29
TSS 19
pH (1)

1Within the range of 6.0 to 9.0 at all times.

The permit authority will obtain the average process water usage flow rate for the new source contact cooling and heating water processes from the permittee.