Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources.

(a) Casting Quench Operations.

PSNS

Open Table
Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
    kg/1,000 kkg (pounds per million pounds) of metal poured
Copper (T) 0.0344 0.0187
Lead (T) 0.0237 0.0116
Zinc (T) 0.0339 0.0129
TTO 0.093 0.0304
Oil and grease (for alternate monitoring) 1.34 0.446

(b) Die Casting Operations.

PSNS

Open Table
Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
    kg/1,000 kkg (pounds per million pounds) of metal poured
Copper (T) 0.0066 0.0036
Lead (T) 0.0046 0.0022
Zinc (T) 0.0066 0.0025
Total phenols 0.0074 0.0026
TTO 0.0196 0.0064
Oil and grease (for alternate monitoring) 0.259 0.0864

(c) Melting Furnace Scrubber Operations.

PSNS

Open Table
Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
    kg/62.3 million Sm3 (pounds per billion SCF) of air scrubbed
Copper (T) 1.56 0.852
Lead (T) 1.07 0.527
Zinc (T) 1.54 0.588
Total phenols 1.74 0.608
TTO 3.95 1.29
Oil and grease (for alternate monitoring) 60.8 20.3

(d) Mold Cooling Operations.

PSNS

Open Table
Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
    kg/1,000 kkg (pounds per million pounds) of metal poured
Copper (T) 0.304 0.166
Lead (T) 0.209 0.103
Zinc (T) 0.3 0.114
TTO 0.821 0.268
Oil and grease (for alternate monitoring) 11.8 3.94

[50 FR 45247, Oct. 30, 1985; 51 FR 21762, June 16, 1986]